M-Bus & Modbus to BACnet/IP gateway BLC-MBUS-250
Shipping costs are not included in the price.
Shipping costs are not included in the price.
Get in touch with us — we offer individual pricing terms for business partners.
Product code: 1C66-34798
Gain Full Control Over Meter Data
...using the BLC-MBUS-250 Gateway

Tired of Gateway Configuration Issues?
Many devices on the market are complicated, unreliable, or do not provide full compatibility with BMS systems. The BLC-MBUS-250 eliminates these problems – offering simple configuration, automatic register mapping, and reliable communication with meters.
Benefits That Make a Difference
Save Time
Use the intuitive web interface and automatic BACnet object naming
Gain Control
Advanced M-Bus master functions and virtual COM mode make meter management easy
Scale the System as Needed
Additional licenses allow you to increase the number of supported meters up to 250 at any time
Increase System Flexibility
With support for M-Bus, Modbus RTU, and Modbus TCP protocols, you don't have to worry about compatibility with new devices
Work Efficiently
Copying meter mapping configurations within or between devices significantly speeds up the integration process
Automate Data Collection
Use the CSV export feature to automate the process of collecting meter readings
Functionalities
FAQ
Do I need special software for configuration?
No. All configuration is done through an intuitive web interface.
Can I connect M-Bus and Modbus meters simultaneously?
Yes. The gateway supports M-Bus, Modbus RTU, and Modbus TCP protocols simultaneously. The important factor is the total number of connected meters.
How many meters does the gateway support?
The BLC-MBUS-250 gateway supports up to 250 meters. The basic version supports 50 meters, and the limit can be increased at any time by purchasing up to 4 additional licenses for 50 meters each.
What transmission speeds are supported?
The BLC-MBUS-250 supports all popular transmission speeds, which can be set independently for each meter.
Can I adjust the meter reading interval?
Yes. The reading interval is configured individually for each meter.
Can I reconfigure a meter, change its address, and transmission speed?
Yes. The gateway allows you to change the address and transmission speed. If specialized manufacturer software is needed, the gateway supports virtual COM mode for that purpose.
Can I change BACnet object names?
Yes. The names and descriptions of BACnet objects can be modified. To simplify the process, the gateway automatically assigns names based on the data read from the meter. The naming scheme can be customized. Supported languages are Polish, English, German, and Lithuanian.
Downloads
Release Notes
Recommended firmware v.1.4.1
Data Sheet BLC-MBUS-250
EU Declaration of Conformity BLC-MBUS-250
User Manual BLC-MBUS-250 (Polish)